Delta Cushion - Lightweight Micro-Bead Positioning Support for Semi-Fowler Pressure Care. - CareSupplies.com Medical Equipment
search
  • Delta Cushion - Lightweight Micro-Bead Positioning Support for Semi-Fowler Pressure Care. - CareSupplies.com Medical Equipment

Delta Cushion - Lightweight Micro-Bead Positioning Support for Semi-Fowler Pressure Care.

  • Triangular Delta Profile for Angled Semi-Fowler Support - the Delta Cushion's triangular profile provides a wedge-angled support surface that corresponds to the body's geometry in the semi-Fowler position, where the torso is at an incline and requires a support surface that follows that incline; the three-dimensional delta shape (600mm x 400mm x 300mm) provides both a sloped surface to support the resident at the semi-Fowler angle and a volumetric body that resists the tendency for the resident to slide down the incline; this is distinct from a flat cushion that would need to be used in combination with separate positional aids to achieve the same angular support.
  • Reduces Pressure, Friction, and Shear at Semi-Fowler Risk Zones - in the semi-Fowler position, the primary pressure and shear risk zones are the sacrum (where gravity and friction forces combine during backrest elevation) and the heels (which remain on the mattress while the upper body is inclined); the Delta Cushion supports the torso in the semi-Fowler position in a way that reduces the sacral shear force by conforming to the body's shape and maintaining the resident at the prescribed angle, reducing the tendency for sacral sliding and shear that causes pressure injury at this site.
  • Micro-Bead Conformability for Variable Body Contours - the micro-bead fill allows the Delta Cushion to adapt its support geometry to the individual resident's body dimensions, accommodating different waist circumferences, pelvic widths, and torso lengths; this is particularly important in the semi-Fowler position where a rigid wedge of fixed dimensions provides the prescribed angle only for residents whose body matches the wedge's proportions; the micro-bead delta surface adapts to the individual, providing correct angular support across a range of body dimensions.
  • MDR Class I - NICE CG179 - Semi-Fowler Indication - NCL-P9710B1HW - MDR 2017/745 Class I positioning device; clinical selection follows occupational therapist or tissue viability assessment per NICE CG179; the prescribed semi-Fowler angle and the Delta Cushion placement must be documented in the care plan alongside the associated skin inspection protocol; product code NCL-P9710B1HW; equipment register records required for CQC Regulation 12 compliance.

Delta Cushion - Triangular Micro-Bead Profile - Semi-Fowler Positioning - Sacral Shear Reduction

The Delta Cushion provides angled postural support in the semi-Fowler position using a triangular micro-bead profile (600 x 400 x 300mm) that follows the body's inclined geometry, maintaining the prescribed backrest angle while reducing sacral shear and friction. The micro-bead fill adapts to individual body dimensions for consistent angular support. Targets the primary pressure and shear risk zones of the semi-Fowler position. MDR 2017/745 Class I positioning device. NICE CG179. NCL-P9710B1HW.

Specifications

SpecificationDetail
ProfileTriangular delta
Fill MaterialUltra-lightweight polystyrene micro-beads
Dimensions600 x 400 x 300mm
Clinical PositionSemi-Fowler postural support
Pressure Care FunctionSacral shear reduction; body-angle maintenance; friction reduction
ReferenceNCL-P9710B1HW
Regulatory StatusMDR 2017/745 Class I medical device

Regulatory Compliance

The Delta Cushion is a Class I medical device under MDR 2017/745. Clinical selection requires occupational therapist or tissue viability assessment per NICE CG179, with the prescribed positioning angle and Delta Cushion placement documented in the care plan. The skin inspection protocol at the sacral zone must be documented as part of the positioning care plan. Equipment register records and MDR conformity documentation must be maintained for CQC Regulation 12 compliance.

Frequently Asked Questions

How does the Delta Cushion differ from the Half Moon Positioning Cushion (ID 232) in semi-Fowler support?

Both the Delta Cushion and the Half Moon Cushion are used in the semi-Fowler position, but they address different aspects of semi-Fowler positioning. The Half Moon Cushion (1350 x 850mm) is a large flat conforming support designed primarily to stabilise the pelvis in the semi-Fowler position - it acts as a broad base beneath the pelvis and lower back that prevents pelvic slide and sacral sitting. The Delta Cushion, by contrast, uses its triangular profile to provide angled volumetric support that corresponds to the inclined geometry of the torso in semi-Fowler; it supports the body at the required backrest angle rather than primarily stabilising the pelvic base. In a complete semi-Fowler positioning system, the Half Moon may be used under the pelvis for pelvic stability while the Delta is used to support the torso at the prescribed incline. The occupational therapist prescribing semi-Fowler positioning must assess whether one or both products are required for the specific resident and document the complete positioning configuration in the care plan.

How is the Delta Cushion oriented relative to the resident's body in the semi-Fowler position?

The Delta Cushion is positioned with its longest face (600mm) along the axis of the resident's torso and its sloped face supporting the resident's back at the prescribed semi-Fowler angle. The narrower end (300mm height) of the triangular profile is positioned toward the foot of the bed, where the cushion tapers to the mattress level, and the taller end is positioned toward the head, providing the elevated support surface. In practice, the Delta Cushion is placed against the resident's back as a back support before the backrest is raised, or it can be placed under the mattress between the mattress and the bed platform at the head end, creating an inclined mattress surface. The occupational therapist must determine and document the specific orientation and placement method for the individual resident, as different placement configurations have different effects on the sacral pressure and shear forces.

NCL-P9710B1HW