The Air Mattress Evacuation Sheet (NCL-AEVS) is permanently fitted beneath an alternating pressure air mattress using deep pockets and elasticated corners. Eight tube outlets maintain full air mattress tube functionality during daily use. Large head and foot pull straps; elongated foot pocket with webbing; patient securing straps. Two operators. Regulatory Reform (Fire Safety) Order 2005 PEEP provision.
| Specification | Detail |
|---|---|
| Reference | NCL-AEVS |
| Designed For | Alternating pressure air mattress systems |
| Tube Outlets | Eight outlets for air mattress tube compatibility |
| Fitting | Deep side pockets; elasticated corners |
| Patient Security | Elongated foot pocket with webbing; securing straps |
| Operator Controls | Large pull straps at head and foot ends |
Residents on alternating pressure air mattresses are among the highest-risk groups for evacuation challenges: they have significant mobility limitations requiring the pressure care, their mattress is connected to pump equipment, and evacuation without a purpose-designed sheet would require disconnecting the pump, removing the air mattress, transferring the patient, and reconnecting or abandoning the pressure care system. The NCL-AEVS eliminates all of these steps, allowing immediate evacuation with the mattress in place. Regulatory Reform (Fire Safety) Order 2005 and CQC Regulation 12 requirements for trained staff and maintained equipment apply.
How do the eight tube outlets preserve air mattress function during normal daily use?
Alternating pressure air mattresses connect to their pump via a series of tubes that run from the pump unit to the individual air cells within the mattress body. These tubes enter the mattress from one end and must not be compressed, kinked, or obstructed to maintain the alternating pressure cycle. The NCL-AEVS has eight pre-positioned outlets through which the tubes pass cleanly from the mattress to the pump, maintaining the full tube run without restriction. Without these outlets, a sheet fitted beneath the air mattress would compress the tube connections and interfere with the pump cycle, compromising the pressure care function the resident depends on.
How does the AEVS attach securely around varying air mattress depths?
Air mattresses vary in depth depending on their specification and inflation state; the NCL-AEVS uses deep side pockets and elasticated corners that accommodate this variation, wrapping around and beneath the mattress base to hold the sheet in position regardless of mattress depth changes during the alternating cycle. The deep pocket design provides more secure retention than simple elasticated edge straps that may slip off a deeper mattress. After installation, confirm the pockets and elasticated corners are correctly engaged around the mattress base at its full inflation depth, and re-check after any pump or mattress servicing.