The Woburn Ultra Low 800 Profiling Bed achieves 90mm minimum floor height for extreme fall prevention while maintaining an 800mm maximum working height matching the standard Woburn range, giving the widest clinical height range in the Woburn family. Built-in auto-regression and standard Trendelenburg address the high sacral pressure risk profile of ultra-low bed residents. SWL 185kg; maximum user weight 175kg. 2399 x 900mm. Low-voltage; IPX4; battery backup; lockable handset. 5-year warranty. MHRA compliant.
| Specification | Detail |
|---|---|
| Frame SWL | 185kg (29 stone) |
| Maximum User Weight | 175kg (27 stone) |
| Height Range | 90 - 800mm |
| Overall Dimensions | 2399 x 900mm |
| Total Bed Weight | 125kg |
| Backrest Angle | Up to 70 degrees |
| Knee Rest Angle | Up to 30 degrees |
| Auto-Regression | Built-in (standard) |
| Trendelenburg | Standard |
| Power Supply | Low-voltage |
| Motor Protection | IPX4 |
| Safety Features | Emergency battery backup; lockable handset |
| Reference | NCL-HLB800.01AR |
| Warranty | 5 years |
| Compliance | MHRA guidelines; NICE NG45 (falls management) |
The Woburn Ultra Low 800 complies with MHRA profiling bed guidelines. Ultra-low bed deployment requires an individual falls risk assessment per NICE NG45 and, where it replaces bed rail use, a best interest decision under the Mental Capacity Act 2005 with documented rationale. SWL and user weight must be verified per MHOR 1992. The height management protocol must be documented in the care plan and included in staff training for each resident. Equipment register records must be maintained for CQC Regulation 12 compliance.
How does the Woburn Ultra Low 800 differ from the Woburn Ultra-Low (ID 198), and when should each be selected?
The two models serve different clinical priorities within the ultra-low category. The Woburn Ultra Low 800 goes from 90mm minimum to 800mm maximum, optimising for the widest clinical height range: the 90mm minimum provides strong fall prevention, and the 800mm maximum ensures full carer ergonomic access without height compromise. The Woburn Ultra-Low goes from 67mm minimum to 640mm maximum, optimising for the absolute lowest floor position at the cost of a lower maximum working height. The 67mm minimum of the Ultra-Low provides near-floor positioning that is clinically appropriate for the very highest fall-risk residents where even the difference between 67mm and 90mm of fall height is considered clinically significant. The Woburn Ultra Low 800 is the better choice when the carer's working height access at the full 800mm range is a clinical priority alongside ultra-low fall management; the Woburn Ultra-Low is the better choice when absolute minimum floor height is the single overriding clinical requirement and the lower 640mm working height is acceptable for the care procedures involved.
Why does the Woburn Ultra Low 800 have a lower SWL than the standard Woburn Profiling Bed?
The standard Woburn Profiling Bed has a 220kg SWL, while the Woburn Ultra Low 800 has a 185kg SWL. The lower SWL reflects the engineering constraints of the ultra-low chassis design: achieving a 90mm minimum floor height requires a fundamentally different frame architecture than a standard profiling bed, with the actuator and lifting mechanism configured to pull the platform very close to the floor level. The structural geometry required for this ultra-low configuration imposes different load distribution characteristics on the frame, which results in a lower SWL rating compared to the standard platform design. Care teams prescribing the Woburn Ultra Low 800 must verify the resident's documented weight does not exceed 175kg per MHOR 1992 before deployment, and must be aware that the 185kg SWL and 175kg maximum user weight of this model are lower than the 220kg and 185kg of the standard Woburn and Woburn Low - residents above 175kg who require ultra-low positioning must be assessed for an alternative solution.