The Eve Shower and Bath Lifter combines a shower chair with a powered bath lowering and raising function, with a low 49.5cm entry height and remote-controlled battery operation for single-carer use. Compatible with the Ascent Pro 200 stand aid. Integrated service module for maintenance alerts. Easy-glide double castors. Battery compatible with all Harvest Healthcare lifting equipment. Optional accessories: digital scales (NCL-HLA009), battery (NCL-HLA016), wall charger (NCL-HLA017). NCL-HLA008.
| Specification | Detail |
|---|---|
| Primary Functions | Shower chair; powered bath lifter |
| Entry Height | 49.5cm |
| Drive | Battery-powered electric lift mechanism |
| Control | Handheld remote |
| Operation | Single-carer |
| Castors | Easy-glide double castors |
| Stand Aid Compatibility | Ascent Pro 200 (NCL-HLA006) |
| Battery Compatibility | All Harvest Healthcare lifting equipment |
| Service Alert | Integrated service module for maintenance and fault notification |
| Optional Extras | Digital scales NCL-HLA009; replacement battery NCL-HLA016; wall charger NCL-HLA017 |
| Reference | NCL-HLA008 |
| Compliance | MHOR 1992; PUWER 1998 (powered equipment); CQC Regulation 12 |
The Eve is powered bathing equipment subject to PUWER 1998, which requires the device to be suitable for its purpose and staff to be trained in correct operation. MHOR 1992 requires a manual handling risk assessment confirming single-carer operation is appropriate for the specific resident and the bathing environment. The service module alerts must be acted upon promptly; operating the Eve with an outstanding service alert may indicate a developing fault and must not be ignored. Battery charge status must be confirmed before each use to confirm sufficient charge for the complete bathing session including lowering and raising. CQC Regulation 12 compliance requires staff training records and equipment maintenance logs.
How does the Eve's powered lift eliminate the manual handling risk during bathing, and what is the carer's role during the session?
In a conventional bath transfer without a powered lift, the carer must physically support and guide the resident's body during the transfer from a seated position into and out of the bath, applying vertical force to manage the resident's body weight through a significant height change; this is one of the highest-risk manual handling tasks in personal care settings and frequently causes carer back injury. The Eve eliminates this manual vertical movement by lowering and raising the resident electrically; the resident is seated on the Eve's ergonomic seat and the carer uses the handheld remote to control the descent into the bath water and the ascent after bathing, without applying any manual force to the vertical movement. The carer's physical role during the session is limited to guiding the Eve into position over the bath, confirming the resident is correctly seated and supported before operating the remote, monitoring the resident throughout the bathing session, assisting with washing tasks from a comfortable standing position at the bathside, and guiding the Eve out of the bath position after raising. The carer's posture throughout is upright and working at a comfortable height; the MHOR 1992 benefit is from eliminating the dynamic load-bearing phase of the bath transfer rather than from reducing overall carer involvement in the session.
What should be confirmed before starting a bathing session with the Eve, and what does the service module alert indicate?
Before each bathing session, the carer must confirm: the battery charge level is sufficient for a full lowering and raising cycle with the specific resident's weight - a low battery that fails mid-session would leave the resident in the bath unable to be raised, requiring an emergency response; the bath is at the appropriate water level and temperature before lowering commences, as the resident cannot easily exit the bath once lowered if conditions are not correct; the Eve's castors are locked before the resident transfers onto the seat; and the remote control is functioning and within range. The service module alert on the Eve's integrated display indicates that a scheduled maintenance interval has been reached or that a technical fault has been detected in the drive mechanism, actuator, or electrical system; the alert must be reported to the equipment manager and the Eve must not be used for bathing sessions until the alert has been addressed by a qualified service technician. Operating powered bathing equipment with an active service alert is a PUWER 1998 compliance issue and a patient safety risk, as the fault indicated by the alert may affect the Eve's lifting reliability during a session.