The Foot Elevator (Foam Ring with Wipe-Clean Cover) provides zero-pressure heel elevation through a circular foam ring fitted with a wipe-clean, vapour-permeable cover that supports NHS IPC decontamination between patient uses. The split design allows easy application and repositioning with minimal carer handling per MHOR 1992. This version is the appropriate specification where NHS IPC policy requires a decontaminatable surface on patient positioning aids. The uncovered version (NCL-FRD) is available for patient-dedicated use.
| Specification | Detail |
|---|---|
| Reference | NCL-FRDC |
| Type | Foam ring with wipe-clean vapour-permeable cover |
| Design Feature | Split for easy fitting and repositioning |
| Cover | Wipe-clean, vapour-permeable |
| Function | Zero-pressure heel elevation |
| Uncovered Version | NCL-FRD (foam ring only) |
NICE CG179 and NICE QS89 specify complete heel suspension as the standard for pressure ulcer prevention. NHS IPC infection control guidelines require that patient positioning aids in care home and clinical settings have surfaces that can be decontaminated between patient uses; the wipe-clean vapour-permeable cover on this model meets this requirement. The vapour-permeable specification additionally maintains skin microclimate per NICE CG179. CQC Regulation 12 (safe care) documentation should include the device in the tissue viability care plan with the cover decontamination schedule recorded.
How should the wipe-clean cover be decontaminated between patient uses?
The wipe-clean cover should be wiped with an NHS IPC-compliant surface disinfectant wipe and allowed to air-dry before the device is reapplied or stored. The disinfectant used should be compatible with vapour-permeable cover materials; check the cover manufacturer guidance to confirm compatibility and avoid material degradation that could compromise the vapour-permeable properties or create skin contact surface defects. Decontamination should be recorded in the care home cleaning schedule as part of the CQC Regulation 12 equipment maintenance record.
Does the wipe-clean cover affect the vapour permeability for the patient's skin?
No. The cover is specifically selected to be vapour-permeable, meaning moisture vapour from the skin can pass through the cover material and dissipate away from the skin surface. This is the same microclimate management principle specified in NICE CG179 for pressure-relieving and offloading devices - that the material in contact with the skin should not trap heat or moisture that would accelerate skin breakdown. The wipe-clean surface property and the vapour-permeable property are both required characteristics of the cover specification and are maintained simultaneously.