Bed Wall Spacer - Protective Bed Accessory for Woburn and Community Ranges. - CareSupplies.com Medical Equipment
search
  • Bed Wall Spacer - Protective Bed Accessory for Woburn and Community Ranges. - CareSupplies.com Medical Equipment

Bed Wall Spacer - Protective Bed Accessory for Woburn and Community Ranges.

  • Maintains Safe Clearance Between the Bed Frame and the Wall - the Bed Wall Spacer fits to the bed frame corners and creates a fixed minimum gap between the bed frame and the adjacent wall, preventing the bed from being pushed flush against the wall during transfers, repositioning, or room cleaning; this minimum clearance has two distinct safety benefits: it prevents the bed frame from damaging electrical sockets, skirting boards, window sills, or other wall fixtures that could be broken or pushed loose by repeated bed contact, and it prevents the bed from creating the fully closed bed-to-wall gap that would otherwise require the Snug Wall Bumper to address the entrapment zone that results.
  • Reduces Electrical Shock Risk at Damaged Sockets - a bed frame pushed against and repeatedly contacting an electrical socket can damage the socket cover, displace the socket faceplate, or crack the socket housing, creating a situation where the live terminals of the socket become accessible at the point where the bed frame contacts the wall; the Bed Wall Spacer prevents this contact damage from occurring, maintaining the integrity of the electrical socket at that wall position throughout the bed's deployment period; this is a specific electrical safety benefit that is distinct from the entrapment and impact protection functions of other bed wall accessories.
  • Sold as a Pair - Tool-Free Corner Installation - the spacer is sold as a pair for use on the two wall-facing corners of the bed frame; the pair creates consistent clearance at both corners simultaneously, ensuring the bed cannot approach the wall at either the head or foot end; installation is tool-free and takes minutes; the spacer can be installed on any corner of the bed frame to accommodate different room configurations where the bed may be positioned against different walls.
  • Woburn Standard and Community Beds - NCL-HLDWLSPC - designed for Woburn Standard and Woburn Community profiling beds; the spacer acts as a complement to the Snug Wall Bumper (ID 210): the spacer prevents the gap from forming by maintaining clearance; where a gap already exists due to room fixtures, the Snug Wall Bumper fills it; where the gap can be prevented entirely, the spacer is the primary intervention; product code NCL-HLDWLSPC.

Bed Wall Spacer - Fixed Clearance Gap - Socket Protection - Tool-Free - Woburn Standard and Community

The Bed Wall Spacer fits to the Woburn bed frame corners to maintain a fixed minimum clearance between the bed and the adjacent wall, preventing the bed from pushing against and damaging electrical sockets, skirting boards, or window sills, and eliminating the bed-to-wall contact that would otherwise require entrapment zone management. Reduces electrical shock risk from socket damage caused by repeated bed frame impact. Sold as a pair for simultaneous two-corner coverage. Tool-free installation. For Woburn Standard and Community beds. NCL-HLDWLSPC.

Specifications

SpecificationDetail
FunctionMaintains fixed minimum clearance between bed frame and wall
SupplySold as a pair (two corners)
InstallationTool-free - any bed frame corner
Protected FixturesElectrical sockets; skirting boards; window sills
Electrical Safety BenefitPrevents socket damage and live terminal exposure from bed frame contact
Compatible BedsWoburn Standard and Woburn Community
ReferenceNCL-HLDWLSPC
ComplianceMHRA bed safety; electrical safety in care settings

Regulatory Compliance

The Bed Wall Spacer supports the care setting's electrical safety obligations by preventing bed frame damage to wall sockets; damaged sockets in a care environment must be reported and assessed per the Electricity at Work Regulations 1989 and may require immediate isolation and repair. The spacer's use must be documented in the bed safety assessment alongside the Snug Wall Bumper assessment (ID 210), since the two accessories address the same zone by different means: the spacer prevents gap formation; the bumper fills a gap that already exists. Equipment register records must include the product code and the bed corners fitted for CQC Regulation 12 compliance.

Frequently Asked Questions

What is the difference between the Bed Wall Spacer and the Snug Wall Bumper, and when should each be used?

The two accessories address the same bed-to-wall zone but at different stages of the risk pathway. The Bed Wall Spacer is a preventive measure: it is fitted to the bed corners to maintain a fixed minimum clearance that prevents the bed from approaching the wall closely enough to create a hazardous gap or to damage wall fixtures. It is appropriate where the room configuration allows the bed to be positioned with a consistent clearance from the wall and where the goal is to prevent the gap and socket damage from occurring at all. The Snug Wall Bumper (ID 210) is a mitigation measure: it fills a gap that already exists between the bed and the wall due to room fixtures such as skirting boards, pipe boxing, or electrical sockets that prevent the bed from being positioned flush against the wall. It is appropriate where a gap is structurally inevitable due to room features that cannot be removed. In ideal circumstances, the spacer is used to prevent the gap from forming; where room features make a gap unavoidable, the bumper fills the resulting space. Both approaches must be documented in the MHRA bed safety assessment for the specific room and bed configuration.

Does the Bed Wall Spacer create an entrapment gap at the point where it spaces the bed from the wall?

The spacer maintains a minimum clearance between the bed frame and the wall rather than allowing the bed to sit flush against the wall. The clearance distance created by the spacer must be assessed against the MHRA bed safety guidance for zone 7 entrapment: if the gap maintained by the spacer falls within the MHRA entrapment dimension range (broadly, a gap that is large enough for a limb to enter but may not allow it to exit), then the spacer creates an entrapment risk rather than eliminating one. The spacer should therefore be selected and fitted with the resulting clearance dimension in mind; if the spacer creates a gap within the hazardous dimension range, either a spacer producing a wider clearance that moves the gap outside the entrapment range should be used, or the resulting gap should be addressed with the Snug Wall Bumper to fill the residual entrapment zone. The care setting's bed safety assessor must measure the resulting bed-to-wall gap after the spacer is fitted and document whether the gap falls within or outside the MHRA entrapment dimension range as part of the zone 7 assessment.

NCL-HLDWLSPC